Assessment of whole body composition with dual energy X-ray absorptiometry in Duchenne muscular dystrophy: Correlation of lean body mass with muscle function

1996 ◽  
Vol 19 (6) ◽  
pp. 777-779 ◽  
Author(s):  
Genaro M.A. Palmieri ◽  
Tulio E. Bertorini ◽  
Judy W. Griffin ◽  
Masanori Igarashi ◽  
James G. Karas
2011 ◽  
Vol 106 (S1) ◽  
pp. S57-S59 ◽  
Author(s):  
Kathryn E. Michel ◽  
Wendy Anderson ◽  
Carolyn Cupp ◽  
Dorothy P. Laflamme

Body condition scoring (BCS) systems primarily assess body fat. Both overweight and underweight animals may have loss of lean tissue that may not be noted using standard BCS systems. Catabolism of lean tissue can occur rapidly, may account for a disproportionate amount of body mass loss in sick cats and can have deleterious consequences for outcome. Therefore, along with evaluation of body fat, patients should undergo evaluation of muscle mass. The aims of the present study were first to evaluate the repeatability and reproducibility of a 4-point feline muscle mass scoring (MMS) system and second to assess the convergent validity of MMS by dual-energy X-ray absorptiometry (DXA). MMS was as follows: 3, normal muscle mass; 2, slight wasting; 1, moderate wasting; 0, severe wasting. For the first aim, forty-four cats were selected for evaluation based on age and BCS, and for the second aim, thirty-three cats were selected based on age, BCS and MMS. Cats were scored by ten different evaluators on three separate occasions. Body composition was determined by DXA. Inter- and intra-rater agreement were assessed using kappa analysis. Correlation between MMS and BCS, age, percentage lean body mass and lean body mass (LBM) was determined using Spearman's rank-order correlation. The MMS showed moderate inter-rater agreement in cats that scored normal or severely wasted (κ = 0·48–0·53). Intra-rater agreement was substantial (κ = 0·71–0·73). The MMS was significantly correlated with BCS (r 0·76, P < 0·0001), age (r − 0·75, P < 0·0001), LBM (g) (r 0·62, P < 0·0001) and percentage LBM (r − 0·49, P < 0·0035). Additional investigation is needed to determine whether the MMS can be refined and to assess its clinical applicability.


Toxins ◽  
2021 ◽  
Vol 13 (4) ◽  
pp. 278
Author(s):  
Dongwoo Lee ◽  
Jaewon Kim ◽  
Ja-Young Oh ◽  
Mi-Hyang Han ◽  
Da-Ye Kim ◽  
...  

We aimed to evaluate muscle mass changes after injection of botulinum toxin (BoNT) in children with spastic hemiplegic cerebral palsy (CP). Children aged between 2 and 12 years who were diagnosed with hemiplegic CP with spastic equinus foot were prospectively recruited and administered BoNT in the affected leg. Lean body mass (LBM) of both legs and total limbs was measured by dual-energy X-ray absorptiometry (DXA) preinjection and 4 and 12 weeks after injection. A total of 15 children were enrolled into the study. LBM of both legs and total limbs increased significantly over 12 weeks of growth. The ratio of LBM of the affected leg to total limbs and to the unaffected leg significantly reduced at 4 weeks after injection compared with preinjection but significantly increased at 12 weeks after injection compared with 4 weeks after injection. In conclusion, the muscle mass of the affected leg after BoNT injection in children with hemiplegic spastic CP decreased at 4 weeks after BoNT injection but significantly recovered after 12 weeks after injection.


2019 ◽  
Vol 9 (1) ◽  
pp. 23-28
Author(s):  
Juliia V. Lavrishcheva ◽  
Aleksandr A. Jakovenko

The aim. To conduct a comparative analysis of the effectiveness of methods for assessing lean body mass in haemodialysis patients. Patients and methods. A total of 317 patients receiving treatment with programmatic bicarbonate haemodialysis in 9 haemodialysis centers in 5 regions of the European part of the Russian Federation were examined for 8.2 ± 5.1 years, among them 171 women and 146 men, the average age was 57.1 ± 11.3 years. Dual-energy X-ray absorptiometry and bioimpedancemetry were used to assess lean body mass. Results. The results of determining the total lean body mass obtained from the results of dual-energy X-ray absorptiometry and bioimpedancemetry were compared using the Bland-Altman method. The correlation coefficient between the indicators was r = 0.994, p < 0.0001, delta (M ± σ) was –0.48 ± 0.91 kg, CI 95% (–0.71)–(–0.26) kg. Conclusion. Dual-energy X-ray absorptiometry has no significant advantages compared with bioimpedancemetry when evaluating lean body mass in haemodialysis patients.


2020 ◽  
Vol 35 (Supplement_3) ◽  
Author(s):  
Natália Tomborelli Bellafronte ◽  
Lorena Vega-Piris ◽  
Paula Garcia Chiarello ◽  
Guillermina Barril Cuadrado

Abstract Background and Aims Chronic kidney disease (CKD) patients frequently have an altered body composition driven by metabolic disorders from the uremic syndrome that usually leads to increased protein catabolism, with obesity and muscle impairment being common conditions associated with worse clinical prognosis and high mortality rates. Therefore, with increased mortality and disability rates of CKD patients in the last quarter of a century and the association of a poor body composition with low survival, routine and longitudinal assessment of body composition could improve clinical outcomes. Due to limited availability of reference methods to assess nutritional status, alternative methods are used. In view of the above, our goal was to evaluate the agreement between multifrequency bioelectrical impedance spectroscopy (BIS) and Dual-energy X-ray Absorptiometry (DXA) for assessment of body composition in CKD. Method Cross-sectional and prospective analyses by DXA (Hologic, GE®) and BIS (BCM, Fresenius Medical Care®) in whole-body (BISWB) and segmental (BISSEG) protocols were performed in CKD non-dialysis-dependent, hemodialysis and peritoneal dialysis (for at least 3 months), and renal transplantation (for at least 6 months) adult (18 ≤ age ≤ 60 years old) patients. Measurements were performed consecutively by the same professional after an 8-hour fast, drainage of the peritoneal dialysate and just after the midweek hemodialysis session. Intraclass correlation coefficient (ICC) and Bland-Altman plots were evaluated for agreement analysis in group and individual levels, respectively; linear regression analysis was performed for bias assessment and development of new equations; ROC curve was constructed for diagnosis of inadequate error tolerance (DXA - BIS &gt; ± 2kg). Results A total of 266 patients were included: 137 men (M) and 129 women (W); 81 were in non-dialysis-dependent treatment, 83 in hemodialysis, 24 in peritoneal dialysis, and 80 had renal transplantation. Total sample had a mean age of 47 ± 10 years old. CKD was secondary to systemic arterial hypertension in 29% of the total sample, to glomerulonephritis in 25%, to diabetes mellitus in 10%, to polycystic kidney in 7%, to glomerulosclerosis and systemic syndromes in 8%, and to other causes and unknown etiology in 20%. Fourteen patients (4 M and 10 W) were in automated and 9 (4 M and 5 W) in continuous ambulatory PD. KTx was by living donor in 18 (14 M and 4 W) and by deceased donor in 63 (34 M and 29 W) patients. The agreement with DXA was greater for BISWB than BISSEG; for fat mass (FM) (ICC in M = 0.89; ICC in W = 0.93) than for fat free mass (FFM) (ICC in M = 0.57; ICC in W = 0.52). Bland-Altman plots showed high limits of agreement (FFM: from -9.51 to 15.64kg; FM: from -7.71 to 7.32kg) with greater bias for FFM as muscular mass increases and for FM in extremes of body fat. The agreement was lower when using the prospective data (body change analysis) (ICC for FFM in M = 0.20; ICC for FFM in W = 0.49; ICC for FM in M = 0.46; ICC for FM in W = 0.58). The factors that interfered in bias between methods were extra to intracellular water ratio (ECW/ICW), body mass index, fat mass index, waist circumference, resistance and reactance (adjusted r2 for FFM = 0.90; r2 for FM = 0.87). FFM had poorer agreement in the last tertile of ECW/ICW sample (ICC in M = 0.69, 0.68 and 0.51; ICC in W = 0.71, 0.74 and 0.38 for first, second and third tertiles, respectively). An ECW/ICW cut-off point of &gt; 0.725 for inadequate error tolerance was determined. New prediction equations for FFM (r2 = 0.91) and FM (r2 = 0.89) presented adequate error tolerance in 55% and 63% in the validation sample compared to 30% and 39% of the original equation, respectively. Conclusion For body composition evaluation in CKD, BIS applied using the whole-body protocol, in normal hydration CKD patients is as reliable as DXA; BIS must be used with caution among overhydrated patients with ECW/ICW &gt; 0.725. The newly developed equations are indicated for greater precision.


1996 ◽  
Vol 28 (Supplement) ◽  
pp. 81
Author(s):  
A D Martin ◽  
S B Heymsfield ◽  
W M Kohrt ◽  
T G Lohman

Radiology ◽  
1992 ◽  
Vol 185 (2) ◽  
pp. 593-598 ◽  
Author(s):  
D O Slosman ◽  
J P Casez ◽  
C Pichard ◽  
T Rochat ◽  
F Fery ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document